How to change the water in a wall-hung boiler: detailed steps and precautions
Wall-hung boilers are common heating equipment in modern homes. Regular maintenance and water changes are the key to ensuring their efficient operation. This article will introduce in detail the steps, tools required, and precautions for changing the water in a wall-mounted boiler to help you complete this task easily.
1. Why do you need to change the water in a wall-mounted boiler?

After long-term use of a wall-mounted boiler, impurities, scale and microorganisms will accumulate in the water, affecting the heat exchange efficiency and even causing equipment failure. Regular water changes can extend the service life of the wall-mounted boiler and improve the heating effect.
2. Preparations before changing water
Before starting the water change, you need to prepare the following tools and materials:
| Tools/Materials | Purpose |
|---|---|
| wrench | For removing the drain valve |
| Bucket or drain pipe | Used to collect discharged old water |
| Soft water or special wall-mounted boiler water | Used to replenish new water |
| Towel or rag | Used to clean up water leaks |
3. Steps to change water in wall-hung boiler
The following are detailed steps for changing the water in a wall-mounted boiler:
| steps | Operating Instructions |
|---|---|
| 1. Turn off the power and gas | Make sure the wall-hung boiler is completely stopped to avoid danger during operation. |
| 2. Find the drain valve | Usually located at the bottom of the boiler, the panel may need to be opened. |
| 3. Connect the drain pipe | Align the drain hose or bucket with the drain valve to prevent water from splashing out. |
| 4. Open the drain valve | Use a wrench to slowly open the drain valve to allow the old water to drain out completely. |
| 5. Flush the system | A small amount of clean water can be injected to flush the pipeline to ensure that impurities are completely removed. |
| 6. Close the drain valve | After the old water is drained, tighten the drain valve to ensure a seal. |
| 7. Add new water | Inject soft water or special wall-mounted boiler water through the water replenishing valve until the pressure gauge shows normal value (usually 1-1.5bar). |
| 8. Exhaust | Open the exhaust valve of the wall-mounted boiler and exhaust the air in the pipe until water flows out. |
| 9. Restart the wall-hung boiler | After confirming that there is no water leakage, restart the wall-hung boiler and check whether it is operating normally. |
4. Precautions when changing water
1.Safety first: Be sure to turn off the power and gas before operation to avoid electric shock or gas leakage.
2.Water quality selection: It is recommended to use soft water or water specially designed for wall-mounted boilers and avoid using tap water to reduce scale formation.
3.Change water regularly: Depending on the frequency of use and water quality, it is recommended to change the water 1-2 times a year.
4.Check pressure: After changing the water, check the pressure gauge to ensure that the pressure is within the normal range (1-1.5bar).
5.Professional help: If you are not familiar with the operation, it is recommended to contact professional maintenance personnel.
5. Frequently Asked Questions
Q1: What should I do if I find that the drain valve is leaking when changing the water?
A1: It may be that the valve sealing ring is aging. It is recommended to replace the sealing ring or contact a professional for repair.
Q2: Why does the wall-mounted boiler not work after changing the water?
A2: There may be air in the pipe that has not been exhausted. Try to exhaust it again. If the problem persists, check the circuit or gas supply.
Summary
Changing the water in a wall-mounted boiler is a simple but important maintenance task. Regular water changes can significantly improve the efficiency and life of the equipment. Follow the steps above and pay attention to safety precautions, and you can easily complete the water change task. If you encounter complex problems, it is recommended to seek professional help in time.
check the details